Return to Test Directory
CRYOGLOBULIN, serum (087-0286)
Test Mnemonic:

CRYOGLOB

Specimen Requirements:
Collection:

7 mL of blood in red-topped vacutainer tube.  (Min: 3mL); Sample must be kept at body temperature (37°C) and hand delivered to the laboratory within 30 minutes of collection.    

Storage/Transport:

Prompt delivery to Sample Management within 30 minutes of collection.  

Specimen Preparation:

Place specimen in 37°C water bath for one hour.  Centrifuge and transfer as much serum as possible without touching the buffy coat into a clean 15 mL screw cap graduated centrifuge tube.  Store serum sample at room temperature. 

Stability:

Room temperature for ≤ 7 days.

Causes for Rejection:

Blood drawn in SST, specimen not deliver at the correct temperature, incomplete and/or incorrect sample identification, improper storage/transport, gross hemolysis and lipemia.                                                                                   

Reference Range:

By report (reports may vary based on instrumentation, patient age and sex).

Turnaround Time:

M-F: within 72 hours

Methodology:

Qualitative Cold Precipitation

Performed:

Special Chemistry; Monday – Friday: 7am – 3:30 pm  

CPT 4 Code:

82595

Note:

Lab must be notified prior to specimen collection. Sample must be kept at body temperature (37°C) and hand delivered to the laboratory within 30 minutes of collection.  Not available on Week-ends.

If applicable, state clinical information that is required to be provided with specimen.

When ordering tests for which Medicare or Medicaid reimbursement will be sought, physicians should only order tests that are medically necessary for the diagnosis or treatment of the patient. Components of the organ or disease panels may be ordered individually. The diagnostic information must substantiate all tests ordered and must be in the form of an ICD-10 code or its verbal equivalent.