Return to Test Directory
COMPLETE BLOOD COUNT WITHOUT DIFFERENTIAL (LAB000619)
Test Mnemonic:

HH

Specimen Requirements:
Collection:

Collect in EDTA (lavender tube). Micro-collection is acceptable.  The specimen should be collected to the appropriate fill volume stated on the collection tube.  The minimum volume required is 90% of the stated tube volume.

Container:

EDTA (lavender tube). Micro-collection

Minimum Volume:

90% of the stated tube volume. Micro-collection minimum 250ul, maximum 500uL

Storage/Transport:

 Room Temperature 4 hours.  If testing cannot be completed within 4 hours sample must be refrigerated at 2-8° C.

Specimen Preparation:

Special Instructions: ECMO specimens should be delivered directly to the Hematopathology lab.

Stability:

Stable Refrigerated at 2-8° Cfor 24 hours.

Causes for Rejection:

Clotted, QNS (quantity not sufficient), identification error, hemolysis

Reference Range:

By report (reports may vary based on instrumentation, patient age and sex)

Turnaround Time:

 STAT: 1 hour; Routine: 4 hours

Methodology:

Automated, multi-parameter counting of red blood cells (RBC) and platelets using electronic resistance detection enhanced by hydrodynamic focusing. The hematocrit is measured utilizing cumulative pulse height detection. Hemoglobin is measured using a sodium lauryl sulfate method. WBC count, and nucleated red blood cells are evaluated using flow cytometry.

Performed:

Samples are accepted 24 hours per day.

Lab:

Galveston Lab, ADC Lab, LCC Lab, CLC Lab

Synonyms:

 Profile/Hemogram, CBC w/out Diff, Hemogram

Clinical Indication:

Monitoring hematological parameters when WBC differential and white/red blood cell morphology is not required.

CPT 4 Code:

85027; if reflexed additional CPT codes may apply; refer to the reflexed test code for applicable codes. Additional charges may apply.

Note:

Critical Values:

WBC< 2.0 x 103/uL

Hemoglobin <7.0 g/dL (age <2 yrs. old),  <5.0 g/dL (age ≥2 yrs. old)

Hematocrit : <21% (<2 yrs. old),  <15.0% (age ≥ 2 yrs. old)

Platelets  <50 or > 1000 x 103/uL

Interfering Substances: Clots or fibrin strands; inappropriate anticoagulant; extremely elevated WBC counts; nucleated red blood cells; sickle cells; clumped platelets; giant platelets, circulating micro-megakaryocytes; hemolysis; electrolyte imbalances; warm or cold agglutinins; elevated plasma lipids; elevated chylomicrons; elevated bilirubin; elevated serum urea nitrogen.

When ordering tests for which Medicare or Medicaid reimbursement will be sought, physicians should only order tests that are medically necessary for the diagnosis or treatment of the patient. Components of the organ or disease panels may be ordered individually. The diagnostic information must substantiate all tests ordered and must be in the form of an ICD-10 code or its verbal equivalent.
Return to Test Directory